12S / 18- to 22-inch propeller
Lower-KV winding for the widest propeller range.
- Peak current
- 73.7A
- Max power
- 3510W
- Resistance
- 42mΩ
- Idle current
- 1.3A @ 10V
Product Code: 0101096178
Availability:In stock
The EMAX ECO II 6218 is a high-torque external-rotor brushless motor for 18- to 22-inch multirotor propellers. Two 12S winding options—180KV and 200KV—use a 24N28P architecture, Ø69.3 × 66.2mm body, M6 threaded propeller shaft and 30 × 30mm mounting pattern. At 431g with wire, it is engineered for large FPV aircraft and heavy-lift propulsion systems.

Published electrical limits and tested thrust values are transcribed from the official EMAX product specification and load-test sheets.
12S / 18- to 22-inch propeller
Lower-KV winding for the widest propeller range.
12S / 18- to 21-inch propeller
Higher-RPM winding for strong large-prop output.

Choose from the complete aircraft backward. Match motor KV to battery voltage, propeller load, ESC rating, aircraft mass, airflow and required thrust. Published ranges are selection guidance; validate the final power system under realistic thermal conditions.
Each bar shows the highest thrust recorded in the official test sheet for that winding. Both bars share a 14.169kg scale.
Maximum values were recorded with a JXF 22 × 10 CF two-blade propeller for 180KV and an HQ 20 × 10 three-blade propeller for 200KV. Bench results are configuration-dependent.
A 6mm bearing section supports the rotating assembly, while the M6 CW threaded propeller interface provides secure retention.
Anodized metal surfaces provide a durable finish for regular installation and service.
A four-hole 30 × 30mm pattern accepts M4 mounting hardware at the airframe interface.
Multi-strand winding is specified for the high-current operating range of this large outrunner.
Concentric bearing support promotes smooth shaft rotation under sustained large-propeller load.
Long, heavy-gauge silicone motor leads provide routing flexibility in large-aircraft installations.

| Motor model | EMAX ECO II 6218 |
|---|---|
| Framework | 24N28P |
| Motor diameter | Ø69.3mm |
| Motor length | 66.2mm |
| Weight | 431g with wire |
| Bearing shaft | Ø6mm |
| Propeller shaft | M6 threaded |
| Shaft direction | CW thread |
| Mounting pattern | 30 × 30mm, four M4 holes |
| Motor leads | 400mm 14 AWG silicone wire |
| Propeller specification | 18–22 inches, KV-dependent |
| KV options | 180KV / 200KV |
The shared mechanical package lets builders select 180KV or 200KV around the intended propeller load without changing the 30 × 30mm four-hole airframe interface.
The 180KV winding supports the broadest published propeller range, while 200KV provides the higher-RPM choice for 18- to 21-inch propellers.
Installation note: Confirm frame clearance, screw engagement, propeller retention, ESC headroom and cooling before operation.

Serious lift with practical value. The ECO II 6218 combines a 24N28P heavy-lift platform with two 12S winding choices for builders matching propeller size, current and thrust targets.
Use only the published voltage and propeller range for the selected winding. Confirm ESC current capability and thermal headroom for the complete aircraft.
| KV | Cells | Propeller | Idle Current | Resistance | Peak Current | Max Power |
|---|---|---|---|---|---|---|
| 180KV | 12S | 18–22″ | 1.3A @ 10V | 42mΩ | 73.7A | 3510W |
| 200KV | 12S | 18–21″ | 1.5A @ 10V | 39mΩ | 79A | 3765W |
Expand a KV option to explore every tested propeller and throttle point from the complete EMAX load-test sheets.
ECO II 6218 Brushless Motor 180KV — GF18 × 10 · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.07 | 2.45 | 1110 | 117.8 | 9.43 | 2381 | 30 |
| 48.06 | 3.60 | 1510 | 173.0 | 8.73 | 2768 | 35 |
| 48.05 | 5.22 | 2018 | 250.8 | 8.05 | 3146 | 40 |
| 48.04 | 7.04 | 2574 | 338.2 | 7.61 | 3525 | 45 |
| 48.02 | 9.41 | 3148 | 451.9 | 6.97 | 3880 | 50 |
| 48.02 | 12.01 | 3645 | 576.7 | 6.32 | 4241 | 55 |
| 47.99 | 14.94 | 4284 | 717.0 | 5.98 | 4597 | 60 |
| 47.97 | 18.62 | 4942 | 893.2 | 5.53 | 4944 | 65 |
| 47.94 | 22.49 | 5623 | 1078.2 | 5.22 | 5276 | 70 |
| 47.91 | 27.10 | 6586 | 1298.4 | 5.07 | 5596 | 75 |
| 47.88 | 32.39 | 7419 | 1550.8 | 4.78 | 5893 | 80 |
| 47.85 | 38.81 | 8406 | 1857.1 | 4.53 | 6188 | 85 |
| 47.82 | 45.22 | 9294 | 2162.4 | 4.30 | 6495 | 90 |
| 47.78 | 52.42 | 10342 | 2504.6 | 4.13 | 6791 | 95 |
| 47.73 | 61.89 | 11533 | 2954.0 | 3.90 | 7080 | Max |
ECO II 6218 Brushless Motor 180KV — HQ20 × 10 · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.07 | 2.71 | 1294 | 130.3 | 9.93 | 2370 | 30 |
| 48.06 | 3.99 | 1778 | 191.8 | 9.27 | 2752 | 35 |
| 48.06 | 5.73 | 2348 | 275.4 | 8.53 | 3130 | 40 |
| 48.03 | 7.69 | 2927 | 369.4 | 7.92 | 3507 | 45 |
| 48.02 | 10.03 | 3480 | 481.6 | 7.23 | 3867 | 50 |
| 48.00 | 12.91 | 4181 | 619.7 | 6.75 | 4209 | 55 |
| 47.99 | 16.35 | 5030 | 784.6 | 6.41 | 4552 | 60 |
| 47.96 | 20.80 | 5910 | 997.6 | 5.92 | 4881 | 65 |
| 47.93 | 24.82 | 6663 | 1189.6 | 5.60 | 5211 | 70 |
| 47.90 | 29.84 | 7592 | 1429.3 | 5.31 | 5515 | 75 |
| 47.88 | 35.30 | 8409 | 1690.2 | 4.98 | 5826 | 80 |
| 47.85 | 41.46 | 9388 | 1983.9 | 4.73 | 6123 | 85 |
| 47.80 | 47.77 | 10312 | 2283.4 | 4.52 | 6433 | 90 |
| 47.76 | 56.33 | 11414 | 2690.3 | 4.24 | 6718 | 95 |
| 47.72 | 64.63 | 12384 | 3084.1 | 4.02 | 7017 | Max |
ECO II 6218 Brushless Motor 180KV — FL21 × 10CF · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.08 | 2.32 | 1205 | 111.5 | 10.80 | 2394 | 30 |
| 48.06 | 3.48 | 1622 | 167.2 | 9.70 | 2779 | 35 |
| 48.07 | 4.81 | 2094 | 231.2 | 9.06 | 3164 | 40 |
| 48.05 | 6.71 | 2671 | 322.4 | 8.28 | 3548 | 45 |
| 48.03 | 8.83 | 3280 | 424.1 | 7.73 | 3906 | 50 |
| 48.02 | 11.31 | 3848 | 543.1 | 7.09 | 4264 | 55 |
| 47.99 | 14.55 | 4663 | 698.3 | 6.68 | 4618 | 60 |
| 47.98 | 17.76 | 5379 | 852.1 | 6.31 | 4968 | 65 |
| 47.95 | 21.70 | 6236 | 1040.5 | 5.99 | 5293 | 70 |
| 47.93 | 26.17 | 6974 | 1254.3 | 5.56 | 5626 | 75 |
| 47.91 | 31.54 | 7951 | 1511.1 | 5.26 | 5909 | 80 |
| 47.88 | 37.22 | 9015 | 1782.1 | 5.06 | 6220 | 85 |
| 47.84 | 43.64 | 9954 | 2087.7 | 4.77 | 6523 | 90 |
| 47.80 | 50.63 | 10958 | 2420.1 | 4.53 | 6824 | 95 |
| 47.74 | 59.87 | 12248 | 2858.2 | 4.29 | 7109 | Max |
ECO II 6218 Brushless Motor 180KV — FL22 × 10CF · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.06 | 2.73 | 1378 | 131.2 | 10.50 | 2370 | 30 |
| 48.06 | 3.95 | 1883 | 189.8 | 9.92 | 2753 | 35 |
| 48.05 | 5.75 | 2500 | 276.3 | 9.05 | 3130 | 40 |
| 48.04 | 7.93 | 3140 | 381.0 | 8.24 | 3503 | 45 |
| 48.03 | 10.17 | 3791 | 488.5 | 7.76 | 3855 | 50 |
| 48.01 | 13.09 | 4483 | 628.5 | 7.13 | 4200 | 55 |
| 47.99 | 16.60 | 5320 | 796.6 | 6.68 | 4545 | 60 |
| 47.96 | 20.22 | 5976 | 969.8 | 6.16 | 4888 | 65 |
| 47.93 | 25.10 | 7049 | 1203.0 | 5.86 | 5195 | 70 |
| 47.90 | 29.64 | 7825 | 1419.8 | 5.51 | 5513 | 75 |
| 47.88 | 35.64 | 8761 | 1706.4 | 5.13 | 5815 | 80 |
| 47.85 | 42.66 | 9939 | 2041.3 | 4.87 | 6099 | 85 |
| 47.80 | 49.79 | 10991 | 2380.0 | 4.62 | 6394 | 90 |
| 47.76 | 58.72 | 12265 | 2804.5 | 4.37 | 6667 | 95 |
| 47.69 | 68.80 | 13539 | 3281.1 | 4.13 | 6951 | Max |
ECO II 6218 Brushless Motor 180KV — JXF22 × 10CF · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.06 | 2.94 | 1468 | 141.3 | 10.39 | 2355 | 30 |
| 48.06 | 4.31 | 2003 | 207.1 | 9.67 | 2741 | 35 |
| 48.05 | 6.18 | 2623 | 296.9 | 8.83 | 3114 | 40 |
| 48.04 | 8.44 | 3313 | 405.5 | 8.17 | 3482 | 45 |
| 48.03 | 11.10 | 4071 | 533.1 | 7.64 | 3826 | 50 |
| 48.00 | 14.50 | 4846 | 696.0 | 6.96 | 4155 | 55 |
| 47.97 | 18.27 | 5730 | 876.4 | 6.54 | 4497 | 60 |
| 47.94 | 22.35 | 6516 | 1071.5 | 6.08 | 4829 | 65 |
| 47.91 | 27.07 | 7431 | 1296.9 | 5.73 | 5146 | 70 |
| 47.89 | 32.65 | 8273 | 1563.6 | 5.29 | 5449 | 75 |
| 47.86 | 38.56 | 9227 | 1845.5 | 5.00 | 5748 | 80 |
| 47.83 | 44.80 | 10289 | 2142.8 | 4.80 | 6056 | 85 |
| 47.79 | 52.43 | 11398 | 2505.6 | 4.55 | 6345 | 90 |
| 47.73 | 62.92 | 12787 | 3003.2 | 4.26 | 6601 | 95 |
| 47.66 | 73.66 | 14169 | 3510.6 | 4.04 | 6866 | Max |
Source: EMAX ECO II 6218 complete load-test workbook. Power and efficiency are taken from the workbook formula results. The final “Max” row retains the workbook label. Results vary by test setup.
ECO II 6218 Brushless Motor 200KV — HQ18 × 9 · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.09 | 2.46 | 1136 | 118.3 | 9.60 | 2591 | 30 |
| 48.08 | 3.56 | 1493 | 171.2 | 8.72 | 2996 | 35 |
| 48.07 | 5.15 | 1997 | 247.6 | 8.07 | 3406 | 40 |
| 48.06 | 6.95 | 2494 | 334.0 | 7.47 | 3818 | 45 |
| 48.05 | 9.30 | 3074 | 446.9 | 6.88 | 4197 | 50 |
| 48.02 | 11.78 | 3692 | 565.7 | 6.53 | 4594 | 55 |
| 48.01 | 14.96 | 4362 | 718.2 | 6.07 | 4987 | 60 |
| 47.99 | 18.17 | 4954 | 872.0 | 5.68 | 5356 | 65 |
| 47.96 | 22.86 | 5829 | 1096.4 | 5.32 | 5692 | 70 |
| 47.93 | 27.26 | 6543 | 1306.6 | 5.01 | 6039 | 75 |
| 47.90 | 32.18 | 7319 | 1541.4 | 4.75 | 6376 | 80 |
| 47.88 | 38.31 | 8235 | 1834.3 | 4.49 | 6707 | 85 |
| 47.85 | 44.18 | 9099 | 2114.0 | 4.30 | 7052 | 90 |
| 47.81 | 51.22 | 9988 | 2448.8 | 4.08 | 7376 | 95 |
| 47.75 | 60.63 | 11147 | 2895.1 | 3.85 | 7672 | Max |
ECO II 6218 Brushless Motor 200KV — GF18 × 10 · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.09 | 3.03 | 1293 | 145.7 | 8.87 | 2546 | 30 |
| 48.08 | 4.52 | 1791 | 217.3 | 8.24 | 2953 | 35 |
| 48.06 | 6.38 | 2340 | 306.6 | 7.63 | 3360 | 40 |
| 48.05 | 8.80 | 2985 | 422.8 | 7.06 | 3748 | 45 |
| 48.03 | 11.37 | 3585 | 546.1 | 6.56 | 4122 | 50 |
| 48.02 | 14.78 | 4282 | 709.7 | 6.03 | 4498 | 55 |
| 47.99 | 18.26 | 5030 | 876.3 | 5.74 | 4876 | 60 |
| 47.96 | 22.74 | 5764 | 1090.6 | 5.29 | 5229 | 65 |
| 47.94 | 28.02 | 6584 | 1343.3 | 4.90 | 5550 | 70 |
| 47.91 | 33.02 | 7474 | 1582.0 | 4.72 | 5888 | 75 |
| 47.87 | 38.49 | 8309 | 1842.5 | 4.51 | 6226 | 80 |
| 47.84 | 46.46 | 9377 | 2222.6 | 4.22 | 6523 | 85 |
| 47.79 | 53.52 | 10273 | 2557.7 | 4.02 | 6851 | 90 |
| 47.74 | 63.49 | 11461 | 3031.0 | 3.78 | 7139 | 95 |
| 47.68 | 71.92 | 12413 | 3429.1 | 3.62 | 7463 | Max |
ECO II 6218 Brushless Motor 200KV — HQ20 × 10 · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.08 | 3.15 | 1472 | 151.5 | 9.72 | 2528 | 30 |
| 48.07 | 4.83 | 2019 | 232.2 | 8.70 | 2930 | 35 |
| 48.06 | 6.76 | 2662 | 324.9 | 8.19 | 3332 | 40 |
| 48.04 | 9.37 | 3354 | 450.1 | 7.45 | 3720 | 45 |
| 48.02 | 12.50 | 4092 | 600.2 | 6.82 | 4077 | 50 |
| 48.01 | 15.75 | 4800 | 756.2 | 6.35 | 4456 | 55 |
| 47.99 | 19.88 | 5739 | 954.0 | 6.02 | 4812 | 60 |
| 47.95 | 24.80 | 6596 | 1189.2 | 5.55 | 5165 | 65 |
| 47.92 | 29.70 | 7454 | 1423.2 | 5.24 | 5477 | 70 |
| 47.90 | 35.16 | 8234 | 1684.2 | 4.89 | 5827 | 75 |
| 47.87 | 41.90 | 9284 | 2005.8 | 4.63 | 6137 | 80 |
| 47.81 | 49.83 | 10513 | 2382.4 | 4.41 | 6427 | 85 |
| 47.76 | 59.30 | 11711 | 2832.2 | 4.13 | 6729 | 90 |
| 47.71 | 67.33 | 12610 | 3212.3 | 3.93 | 7045 | 95 |
| 47.65 | 79.02 | 13857 | 3765.3 | 3.68 | 7338 | Max |
ECO II 6218 Brushless Motor 200KV — FL19 × 10CF · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.07 | 2.32 | 1022 | 111.5 | 9.16 | 2612 | 30 |
| 48.07 | 3.31 | 1376 | 159.1 | 8.65 | 3021 | 35 |
| 48.06 | 4.62 | 1801 | 222.0 | 8.11 | 3428 | 40 |
| 48.05 | 6.49 | 2307 | 311.8 | 7.40 | 3836 | 45 |
| 48.04 | 8.21 | 2802 | 394.4 | 7.10 | 4227 | 50 |
| 48.03 | 10.64 | 3394 | 511.0 | 6.64 | 4629 | 55 |
| 48.02 | 13.12 | 3998 | 630.0 | 6.35 | 5032 | 60 |
| 47.99 | 16.32 | 4603 | 783.2 | 5.88 | 5408 | 65 |
| 47.96 | 20.82 | 5398 | 998.5 | 5.41 | 5756 | 70 |
| 47.93 | 24.53 | 6115 | 1175.7 | 5.20 | 6104 | 75 |
| 47.91 | 29.41 | 6902 | 1409.0 | 4.90 | 6452 | 80 |
| 47.89 | 33.55 | 7363 | 1606.7 | 4.58 | 6819 | 85 |
| 47.85 | 40.10 | 8474 | 1918.8 | 4.42 | 7139 | 90 |
| 47.81 | 46.44 | 9340 | 2220.3 | 4.21 | 7478 | 95 |
| 47.78 | 54.02 | 10213 | 2581.1 | 3.96 | 7804 | Max |
ECO II 6218 Brushless Motor 200KV — FL20 × 10CF · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.07 | 2.53 | 1160 | 121.6 | 9.54 | 2590 | 30 |
| 48.06 | 3.73 | 1557 | 179.3 | 8.69 | 2994 | 35 |
| 48.05 | 5.13 | 2036 | 246.5 | 8.26 | 3404 | 40 |
| 48.04 | 6.96 | 2578 | 334.4 | 7.71 | 3810 | 45 |
| 48.02 | 9.30 | 3164 | 446.6 | 7.08 | 4196 | 50 |
| 48.02 | 11.93 | 3818 | 572.9 | 6.66 | 4584 | 55 |
| 47.99 | 15.00 | 4457 | 719.9 | 6.19 | 4981 | 60 |
| 47.97 | 18.57 | 5214 | 890.8 | 5.85 | 5344 | 65 |
| 47.95 | 22.31 | 5883 | 1069.8 | 5.50 | 5698 | 70 |
| 47.92 | 26.90 | 6730 | 1289.0 | 5.22 | 6036 | 75 |
| 47.89 | 32.16 | 7564 | 1540.1 | 4.91 | 6365 | 80 |
| 47.86 | 38.62 | 8674 | 1848.4 | 4.69 | 6692 | 85 |
| 47.82 | 44.01 | 9167 | 2104.6 | 4.36 | 7049 | 90 |
| 47.78 | 52.24 | 10179 | 2496.0 | 4.08 | 7355 | 95 |
| 47.74 | 60.71 | 11309 | 2898.3 | 3.90 | 7671 | Max |
ECO II 6218 Brushless Motor 200KV — FL21 × 10CF · 15 test points
| Voltage V | Current A | Thrust g | Power W | Efficiency g/W | Speed RPM | Throttle % |
|---|---|---|---|---|---|---|
| 48.07 | 2.80 | 1377 | 134.6 | 10.23 | 2551 | 30 |
| 48.06 | 4.23 | 1864 | 203.3 | 9.17 | 2952 | 35 |
| 48.05 | 6.03 | 2425 | 289.7 | 8.37 | 3364 | 40 |
| 48.04 | 8.20 | 3057 | 393.9 | 7.76 | 3761 | 45 |
| 48.02 | 10.75 | 3712 | 516.2 | 7.19 | 4137 | 50 |
| 48.00 | 13.54 | 4400 | 649.9 | 6.77 | 4525 | 55 |
| 47.98 | 17.61 | 5396 | 844.9 | 6.39 | 4877 | 60 |
| 47.96 | 21.81 | 6152 | 1046.0 | 5.88 | 5241 | 65 |
| 47.93 | 25.98 | 6999 | 1245.2 | 5.62 | 5593 | 70 |
| 47.89 | 31.34 | 7835 | 1500.9 | 5.22 | 5914 | 75 |
| 47.86 | 37.21 | 8899 | 1780.9 | 5.00 | 6234 | 80 |
| 47.83 | 44.28 | 9887 | 2117.9 | 4.67 | 6551 | 85 |
| 47.79 | 52.27 | 11026 | 2498.0 | 4.41 | 6856 | 90 |
| 47.73 | 60.68 | 12003 | 2896.3 | 4.14 | 7176 | 95 |
| 47.69 | 70.58 | 13123 | 3366.0 | 3.90 | 7486 | Max |
Source: EMAX ECO II 6218 complete load-test workbook. Power and efficiency are taken from the workbook formula results. The final “Max” row retains the workbook label. Results vary by test setup.